+12
−3
Loading
The formula in the datasheet for oversampling time conversion seems to be valid when device is at full speed using the maximum number of SDO lines. The driver currently support only 1 SDO line. The correct formula is: t_convert = T_CONVERT_0_NS + T_CONVERT_X_NS*(x - 1)*num_channel/number_of_sdo_lines. It will produce larger delays than what is currently set, but some devices actually require it. Signed-off-by:Julien Stephan <jstephan@baylibre.com> Reviewed-by:
David Lechner <dlechner@baylibre.com> Link: https://patch.msgid.link/20241030-ad7380-add-adaq4380-4-support-v4-2-864ff02babae@baylibre.com Signed-off-by:
Jonathan Cameron <Jonathan.Cameron@huawei.com>