Commit 2d253726 authored by Harshal Chaudhari's avatar Harshal Chaudhari Committed by Jakub Kicinski
Browse files

net: mvpp2: cls: Fixed Non IP flow, with vlan tag flow defination.



Non IP flow, with vlan tag not working as expected while
running below command for vlan-priority. fixed that.

ethtool -N eth1 flow-type ether vlan 0x8000 vlan-mask 0x1fff action 0 loc 0

Fixes: 1274daed ("net: mvpp2: cls: Add steering based on vlan Id and priority.")
Signed-off-by: default avatarHarshal Chaudhari <hchaudhari@marvell.com>
Reviewed-by: default avatarMaxime Chevallier <maxime.chevallier@bootlin.com>
Link: https://patch.msgid.link/20250225042058.2643838-1-hchaudhari@marvell.com


Signed-off-by: default avatarJakub Kicinski <kuba@kernel.org>
parent bc23d4e3
Loading
Loading
Loading
Loading
+1 −1
Original line number Diff line number Diff line
@@ -324,7 +324,7 @@ static const struct mvpp2_cls_flow cls_flows[MVPP2_N_PRS_FLOWS] = {
		       MVPP2_PRS_RI_VLAN_MASK),
	/* Non IP flow, with vlan tag */
	MVPP2_DEF_FLOW(MVPP22_FLOW_ETHERNET, MVPP2_FL_NON_IP_TAG,
		       MVPP22_CLS_HEK_OPT_VLAN,
		       MVPP22_CLS_HEK_TAGGED,
		       0, 0),
};