+16
−2
Loading
SMPT contains config detection info that describes opcode, address, and dummy cycles to read sector map config. The dummy cycles parameter can be SMPT_CMD_READ_DUMMY_IS_VARIABLE and in that case nor->read_dummy (initialized as 0) is used. In Infineon flash chips, Read Any Register command with variable dummy cycle is defined in SMPT. S25Hx/S28Hx flash has 0 dummy cycle by default to read volatile regiters and nor->read_dummy can work. S25FS-S flash has 8 dummy cycles so we need a hook that can fix dummy cycles with actually used value. Inroduce smpt_read_dummy() in struct spi_nor_fixups. It is called when the dummy cycle field in SMPT config detection is 'varialble'. Reviewed-by:Tudor Ambarus <tudor.ambarus@linaro.org> Tested-by: Marek Vasut <marek.vasut+renesas@mailbox.org> # S25FS512S Signed-off-by:
Takahiro Kuwano <Takahiro.Kuwano@infineon.com> Signed-off-by:
Pratyush Yadav <pratyush@kernel.org>