+19
−0
Loading
The error-signalling (ES) is a mandatory functionality for CAN CC and CAN FD to report CAN frame format violations by sending an error-frame signal on the bus. A so-called 'mixed-mode' is intended to have (XL-tolerant) CAN FD nodes and CAN XL nodes on one CAN segment, where the FD-controllers can talk CC/FD and the XL-controllers can talk CC/FD/XL. This mixed-mode utilizes the error-signalling for sending CC/FD/XL frames. The CANXL-only mode disables the error-signalling in the CAN XL controller. This mode does not allow CC/FD frames to be sent but additionally offers a CAN XL transceiver mode switching (TMS). Configured with CAN_CTRLMODE_FD and CAN_CTRLMODE_XL this leads to: FD=0 XL=0 CC-only mode (ES=1) FD=1 XL=0 FD/CC mixed-mode (ES=1) FD=1 XL=1 XL/FD/CC mixed-mode (ES=1) FD=0 XL=1 XL-only mode (ES=0, TMS optional) The helper function can_dev_in_xl_only_mode() determines the required value to disable error signalling in the CAN XL controller. Signed-off-by:Oliver Hartkopp <socketcan@hartkopp.net> Link: https://patch.msgid.link/20251126-canxl-v8-7-e7e3eb74f889@pengutronix.de Signed-off-by:
Marc Kleine-Budde <mkl@pengutronix.de>