+4
−0
+6
−0
Loading
Interrupt control structure (union hv_interupt_control) has different fields when it comes to x86 vs ARM64. Bring in the correct structure from HyperV header files and adjust the existing interrupt routing code accordingly. Signed-off-by:Jinank Jain <jinankjain@microsoft.com> Signed-off-by:
Anirudh Rayabharam (Microsoft) <anirudh@anirudhrb.com> Signed-off-by:
Wei Liu <wei.liu@kernel.org>