Commit ca374f5d authored by Damien Le Moal's avatar Damien Le Moal Committed by Martin K. Petersen
Browse files

scsi: pm8001: Fix le32 values handling in pm80xx_set_sas_protocol_timer_config()

All fields of the SASProtocolTimerConfig structure have the __le32 type.
As such, use cpu_to_le32() to initialize them. This change suppresses many
sparse warnings:

warning: incorrect type in assignment (different base types)
   expected restricted __le32 [addressable] [usertype] pageCode
   got int

Note that the check to limit the value of the STP_IDLE_TMO field is removed
as this field is initialized using the fixed (and small) value defined by
the STP_IDLE_TIME macro.

The pm8001_dbg() calls printing the values of the SASProtocolTimerConfig
structure fileds are changed to use le32_to_cpu() to present the values in
human readable form.

Link: https://lore.kernel.org/r/20220220031810.738362-9-damien.lemoal@opensource.wdc.com


Fixes: a6cb3d01 ("[SCSI] pm80xx: thermal, sas controller config and error handling update")
Reviewed-by: default avatarJack Wang <jinpu.wang@ionos.com>
Signed-off-by: default avatarDamien Le Moal <damien.lemoal@opensource.wdc.com>
Signed-off-by: default avatarMartin K. Petersen <martin.petersen@oracle.com>
parent bb225b12
Loading
Loading
Loading
Loading
+25 −27
Original line number Diff line number Diff line
@@ -1245,43 +1245,41 @@ pm80xx_set_sas_protocol_timer_config(struct pm8001_hba_info *pm8001_ha)
	circularQ = &pm8001_ha->inbnd_q_tbl[0];
	payload.tag = cpu_to_le32(tag);

	SASConfigPage.pageCode        =  SAS_PROTOCOL_TIMER_CONFIG_PAGE;
	SASConfigPage.MST_MSI         =  3 << 15;
	SASConfigPage.STP_SSP_MCT_TMO =  (STP_MCT_TMO << 16) | SSP_MCT_TMO;
	SASConfigPage.STP_FRM_TMO     = (SAS_MAX_OPEN_TIME << 24) |
				(SMP_MAX_CONN_TIMER << 16) | STP_FRM_TIMER;
	SASConfigPage.STP_IDLE_TMO    =  STP_IDLE_TIME;

	if (SASConfigPage.STP_IDLE_TMO > 0x3FFFFFF)
		SASConfigPage.STP_IDLE_TMO = 0x3FFFFFF;


	SASConfigPage.OPNRJT_RTRY_INTVL =         (SAS_MFD << 16) |
						SAS_OPNRJT_RTRY_INTVL;
	SASConfigPage.Data_Cmd_OPNRJT_RTRY_TMO =  (SAS_DOPNRJT_RTRY_TMO << 16)
						| SAS_COPNRJT_RTRY_TMO;
	SASConfigPage.Data_Cmd_OPNRJT_RTRY_THR =  (SAS_DOPNRJT_RTRY_THR << 16)
						| SAS_COPNRJT_RTRY_THR;
	SASConfigPage.MAX_AIP =  SAS_MAX_AIP;
	SASConfigPage.pageCode = cpu_to_le32(SAS_PROTOCOL_TIMER_CONFIG_PAGE);
	SASConfigPage.MST_MSI = cpu_to_le32(3 << 15);
	SASConfigPage.STP_SSP_MCT_TMO =
		cpu_to_le32((STP_MCT_TMO << 16) | SSP_MCT_TMO);
	SASConfigPage.STP_FRM_TMO =
		cpu_to_le32((SAS_MAX_OPEN_TIME << 24) |
			    (SMP_MAX_CONN_TIMER << 16) | STP_FRM_TIMER);
	SASConfigPage.STP_IDLE_TMO = cpu_to_le32(STP_IDLE_TIME);

	SASConfigPage.OPNRJT_RTRY_INTVL =
		cpu_to_le32((SAS_MFD << 16) | SAS_OPNRJT_RTRY_INTVL);
	SASConfigPage.Data_Cmd_OPNRJT_RTRY_TMO =
		cpu_to_le32((SAS_DOPNRJT_RTRY_TMO << 16) | SAS_COPNRJT_RTRY_TMO);
	SASConfigPage.Data_Cmd_OPNRJT_RTRY_THR =
		cpu_to_le32((SAS_DOPNRJT_RTRY_THR << 16) | SAS_COPNRJT_RTRY_THR);
	SASConfigPage.MAX_AIP = cpu_to_le32(SAS_MAX_AIP);

	pm8001_dbg(pm8001_ha, INIT, "SASConfigPage.pageCode 0x%08x\n",
		   SASConfigPage.pageCode);
		   le32_to_cpu(SASConfigPage.pageCode));
	pm8001_dbg(pm8001_ha, INIT, "SASConfigPage.MST_MSI  0x%08x\n",
		   SASConfigPage.MST_MSI);
		   le32_to_cpu(SASConfigPage.MST_MSI));
	pm8001_dbg(pm8001_ha, INIT, "SASConfigPage.STP_SSP_MCT_TMO  0x%08x\n",
		   SASConfigPage.STP_SSP_MCT_TMO);
		   le32_to_cpu(SASConfigPage.STP_SSP_MCT_TMO));
	pm8001_dbg(pm8001_ha, INIT, "SASConfigPage.STP_FRM_TMO  0x%08x\n",
		   SASConfigPage.STP_FRM_TMO);
		   le32_to_cpu(SASConfigPage.STP_FRM_TMO));
	pm8001_dbg(pm8001_ha, INIT, "SASConfigPage.STP_IDLE_TMO  0x%08x\n",
		   SASConfigPage.STP_IDLE_TMO);
		   le32_to_cpu(SASConfigPage.STP_IDLE_TMO));
	pm8001_dbg(pm8001_ha, INIT, "SASConfigPage.OPNRJT_RTRY_INTVL  0x%08x\n",
		   SASConfigPage.OPNRJT_RTRY_INTVL);
		   le32_to_cpu(SASConfigPage.OPNRJT_RTRY_INTVL));
	pm8001_dbg(pm8001_ha, INIT, "SASConfigPage.Data_Cmd_OPNRJT_RTRY_TMO  0x%08x\n",
		   SASConfigPage.Data_Cmd_OPNRJT_RTRY_TMO);
		   le32_to_cpu(SASConfigPage.Data_Cmd_OPNRJT_RTRY_TMO));
	pm8001_dbg(pm8001_ha, INIT, "SASConfigPage.Data_Cmd_OPNRJT_RTRY_THR  0x%08x\n",
		   SASConfigPage.Data_Cmd_OPNRJT_RTRY_THR);
		   le32_to_cpu(SASConfigPage.Data_Cmd_OPNRJT_RTRY_THR));
	pm8001_dbg(pm8001_ha, INIT, "SASConfigPage.MAX_AIP  0x%08x\n",
		   SASConfigPage.MAX_AIP);
		   le32_to_cpu(SASConfigPage.MAX_AIP));

	memcpy(&payload.cfg_pg, &SASConfigPage,
			 sizeof(SASProtocolTimerConfig_t));