Commit d4f408cd authored by Evgeny Boger's avatar Evgeny Boger Committed by Sebastian Reichel
Browse files

power: supply: axp20x_battery: properly report current when discharging



As stated in [1], negative current values are used for discharging
batteries.

AXP PMICs internally have two different ADC channels for shunt current
measurement: one used during charging and one during discharging.
The values reported by these ADCs are unsigned.
While the driver properly selects ADC channel to get the data from,
it doesn't apply negative sign when reporting discharging current.

[1] Documentation/ABI/testing/sysfs-class-power

Signed-off-by: default avatarEvgeny Boger <boger@wirenboard.com>
Acked-by: default avatarChen-Yu Tsai <wens@csie.org>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent ba18dad0
Loading
Loading
Loading
Loading
+6 −7
Original line number Diff line number Diff line
@@ -186,7 +186,6 @@ static int axp20x_battery_get_prop(struct power_supply *psy,
				   union power_supply_propval *val)
{
	struct axp20x_batt_ps *axp20x_batt = power_supply_get_drvdata(psy);
	struct iio_channel *chan;
	int ret = 0, reg, val1;

	switch (psp) {
@@ -266,12 +265,12 @@ static int axp20x_battery_get_prop(struct power_supply *psy,
		if (ret)
			return ret;

		if (reg & AXP20X_PWR_STATUS_BAT_CHARGING)
			chan = axp20x_batt->batt_chrg_i;
		else
			chan = axp20x_batt->batt_dischrg_i;

		ret = iio_read_channel_processed(chan, &val->intval);
		if (reg & AXP20X_PWR_STATUS_BAT_CHARGING) {
			ret = iio_read_channel_processed(axp20x_batt->batt_chrg_i, &val->intval);
		} else {
			ret = iio_read_channel_processed(axp20x_batt->batt_dischrg_i, &val1);
			val->intval = -val1;
		}
		if (ret)
			return ret;