Commit ef8df816 authored by Armin Wolf's avatar Armin Wolf Committed by Guenter Roeck
Browse files

hwmon: (dell-smm) Add Dell OptiPlex 7060 to DMI table

The BIOS on this machine is buggy and will in some cases return
an error when trying to get the fan state, but reading of the
RPM values and the temperature sensors still works.

Closes: https://github.com/vitorafsr/i8kutils/issues/38


Signed-off-by: default avatarArmin Wolf <W_Armin@gmx.de>
Acked-by: default avatarPali Rohár <pali@kernel.org>
Link: https://lore.kernel.org/r/20240628214723.19665-1-W_Armin@gmx.de


Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
parent 38b2b022
Loading
Loading
Loading
Loading
+2 −0
Original line number Diff line number Diff line
@@ -360,6 +360,8 @@ Firmware Bug Affected Machines
======================================================= =================
Reading of fan states return spurious errors.           Precision 490

                                                        OptiPlex 7060

Reading of fan types causes erratic fan behaviour.      Studio XPS 8000

                                                        Studio XPS 8100
+7 −0
Original line number Diff line number Diff line
@@ -1263,6 +1263,13 @@ static const struct dmi_system_id i8k_dmi_table[] __initconst = {
			DMI_MATCH(DMI_PRODUCT_NAME, "MP061"),
		},
	},
	{
		.ident = "Dell OptiPlex 7060",
		.matches = {
			DMI_MATCH(DMI_SYS_VENDOR, "Dell Inc."),
			DMI_EXACT_MATCH(DMI_PRODUCT_NAME, "OptiPlex 7060"),
		},
	},
	{
		.ident = "Dell Precision",
		.matches = {