drm/amd/display: force connector state when bpc changes during compliance
[Why] During DP DSC compliance tests, bpc requested would change between sub-tests, which requires stream to be recommited. [How] Force connector to disconnect and reconnect whenever there is a bpc change in automated test. Reviewed-by: Jerry Zuo <Jerry.Zuo@amd.com> Acked-by: Alan Liu <HaoPing.Liu@amd.com> Signed-off-by: Qingqing Zhuo <qingqing.zhuo@amd.com> Signed-off-by: hersen wu <hersenxs.wu@amd.com> Tested-by: Daniel Wheeler <daniel.wheeler@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com>