Commit 50f0ff7c authored by Andrew Davis's avatar Andrew Davis Committed by Sebastian Reichel
Browse files

power: supply: bq27xxx: Move health reading out of update loop



Most of the functions that read values return a status and put the value
itself in an a function parameter. Update health reading to match.

As health is not checked for changes as part of the update loop, remove
the read of this from the periodic update loop. This saves I2C/1W
bandwidth. It also means we do not have to cache it, fresh values are
read when requested.

Signed-off-by: default avatarAndrew Davis <afd@ti.com>
Link: https://lore.kernel.org/r/20240325203129.150030-6-afd@ti.com


Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent 656489ac
Loading
Loading
Loading
Loading
+18 −12
Original line number Diff line number Diff line
@@ -1777,19 +1777,26 @@ static bool bq27xxx_battery_capacity_inaccurate(struct bq27xxx_device_info *di,
		return false;
}

static int bq27xxx_battery_read_health(struct bq27xxx_device_info *di)
static int bq27xxx_battery_read_health(struct bq27xxx_device_info *di,
				       union power_supply_propval *val)
{
	int health;

	/* Unlikely but important to return first */
	if (unlikely(bq27xxx_battery_overtemp(di, di->cache.flags)))
		return POWER_SUPPLY_HEALTH_OVERHEAT;
	if (unlikely(bq27xxx_battery_undertemp(di, di->cache.flags)))
		return POWER_SUPPLY_HEALTH_COLD;
	if (unlikely(bq27xxx_battery_dead(di, di->cache.flags)))
		return POWER_SUPPLY_HEALTH_DEAD;
	if (unlikely(bq27xxx_battery_capacity_inaccurate(di, di->cache.flags)))
		return POWER_SUPPLY_HEALTH_CALIBRATION_REQUIRED;
		health = POWER_SUPPLY_HEALTH_OVERHEAT;
	else if (unlikely(bq27xxx_battery_undertemp(di, di->cache.flags)))
		health = POWER_SUPPLY_HEALTH_COLD;
	else if (unlikely(bq27xxx_battery_dead(di, di->cache.flags)))
		health = POWER_SUPPLY_HEALTH_DEAD;
	else if (unlikely(bq27xxx_battery_capacity_inaccurate(di, di->cache.flags)))
		health = POWER_SUPPLY_HEALTH_CALIBRATION_REQUIRED;
	else
		health = POWER_SUPPLY_HEALTH_GOOD;

	return POWER_SUPPLY_HEALTH_GOOD;
	val->intval = health;

	return 0;
}

static bool bq27xxx_battery_is_full(struct bq27xxx_device_info *di, int flags)
@@ -1874,7 +1881,6 @@ static void bq27xxx_battery_update_unlocked(struct bq27xxx_device_info *di)
	if (cache.flags >= 0) {
		cache.capacity = bq27xxx_battery_read_soc(di);
		di->cache.flags = cache.flags;
		cache.health = bq27xxx_battery_read_health(di);

		/*
		 * On gauges with signed current reporting the current must be
@@ -2092,7 +2098,7 @@ static int bq27xxx_battery_get_property(struct power_supply *psy,
		ret = bq27xxx_battery_pwr_avg(di, val);
		break;
	case POWER_SUPPLY_PROP_HEALTH:
		ret = bq27xxx_simple_value(di->cache.health, val);
		ret = bq27xxx_battery_read_health(di, val);
		break;
	case POWER_SUPPLY_PROP_MANUFACTURER:
		val->strval = BQ27XXX_MANUFACTURER;
+0 −1
Original line number Diff line number Diff line
@@ -49,7 +49,6 @@ struct bq27xxx_access_methods {
struct bq27xxx_reg_cache {
	int capacity;
	int flags;
	int health;
};

struct bq27xxx_device_info {