iio: magnetometer: tlv493d: remove erroneous shift in X-axis data

TLV493D_BX2_MAG_X_AXIS_LSB is defined as GENMASK(7, 4). FIELD_GET()
already right-shifts bits [7:4] to [3:0], so the additional >> 4
discards most of the X-axis low nibble. The Y and Z axes correctly
omit this extra shift. Remove it.

Fixes: 106511d280 ("iio: magnetometer: add support for Infineon TLV493D 3D Magentic sensor")
Signed-off-by: Antoniu Miclaus <antoniu.miclaus@analog.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Antoniu Miclaus
2026-02-10 18:49:50 +02:00
committed by Jonathan Cameron
parent a318cfc085
commit 82ee91d6b1

View File

@@ -171,7 +171,7 @@ static s16 tlv493d_get_channel_data(u8 *b, enum tlv493d_channels ch)
switch (ch) {
case TLV493D_AXIS_X:
val = FIELD_GET(TLV493D_BX_MAG_X_AXIS_MSB, b[TLV493D_RD_REG_BX]) << 4 |
FIELD_GET(TLV493D_BX2_MAG_X_AXIS_LSB, b[TLV493D_RD_REG_BX2]) >> 4;
FIELD_GET(TLV493D_BX2_MAG_X_AXIS_LSB, b[TLV493D_RD_REG_BX2]);
break;
case TLV493D_AXIS_Y:
val = FIELD_GET(TLV493D_BY_MAG_Y_AXIS_MSB, b[TLV493D_RD_REG_BY]) << 4 |